The calculation of static empirical method are used to estimate bearing capacity of close ended-spun pile types with a diameter of 50 cm based on the data of N-SPT. The data shows that the hard stratum is found about 10 meters depth in most places in Jakarta. The performed methods are: Collecting, selecting, grouping and plotting the data location on Jakarta map. To achieve those targets, this research uses the data in the form of soil investigation equipped with boring logs and N-SPT from several locations in Jakarta. This study aims to map the bearing capacity of the foundation and the distribution of the depth of the hard stratum to support it. The type and the location where the stratum hold the foundation affect its bearing capacity value.